With our excellent administration, strong technical capability and strict excellent control method, we carry on to offer our clients with responsible good quality, reasonable costs and great companies. We intention at becoming considered one of your most responsible partners and earning your pleasure for Linear Heat Detection Wire, Mist Spray System, Linear Heat Automation System, Wanting on the long run, a protracted way to go, continually striving to become the all team with full enthusiasm, one hundred times the confidence and put our company created a beautiful environment, advanced merchandise, good quality first-class modern business and get the job done hard!
OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1) – Anbesec Detail:

High-pressure plunger pump

1

High pressure plunger pump  is one of the core components of high pressure water mist system, our company high-pressure plunger pump adopts foreign advanced technology, it has the advantages of long service life and stable performance. Liquid end is made of brass production.

 

High-pressure plunger pump main technical parameters:

specifications

Flow rate(L/min)

Working pressure(Mpa)

power(KW)

Rotating speed

(r/min)

origin

HAWK-HFR80FR

80

28

42

1450

Italy

Pressure-stabilizing pump

2

The pressure stabilizing pump is to stabilize the pressure in the pipeline. After the zone valve is opened, the pipeline pressure is under The pressure stabilizing pump will start automatically. After running for more than 10 seconds, the pressure still cannot reach 16bar, automatically start the high-pressure main pump. The stabilizer pump is made of stainless steel.

 

 

Pump motor

水泵电机

Our company’s high-pressure water mist automatic fire extinguishing system adopts frequency conversion, speed-adjustable, three-phase asynchronous motor.

When selecting  high pressure water mist fire extinguishing system, the rated speed of the motor should meet the speed requirements of the pump, selection of the power of the motor should be based on the working pressure and the flow rate of the water pump.

N=2PQ*10-2

N—-Motor power(Kw);

O—–Working pressure of water pump(MPa);

P—-Flow of water pump(L/min)

High pressure water mist nozzle

4

 

The high-pressure water mist nozzle consists of the main body of the nozzle, the swirl core of the nozzle, and the nozzle main body, filter screen, filter screen sleeve, etc. Under certain water pressure, the water is atomized by centrifugation, impact, jet and other methods.

 

Community-verified icon

 

Technical parameters:

Specification model Rated flow rate(L/min) Minimum working pressure (MPa) Maximum installation distance (m) Height of installation (m)
XSWT0.5/10 5 10 3 According to the design specification
XSWT0.7/10 7 10 3
XSWT1.0/10 10 10 3
XSWT1.2/10 12 10 3
XSWT1.5/10 15 10 3

Pressure regulating relief valve

5

 

The pressure regulating relief valve is connected with the high-pressure water pump and the water tank, when the main pump pressure is too high, the discharged water can flow back to the storage tank. The pressure regulating relief valve is made of brass.

 

Safety relief valve

6

The pressure value of relief action of the safety relief valve is 16.8MPa, and the safety relief valve also known as safety overflow valve is an automatic pressure relief device driven by medium pressure. The safety relief valve is made of stainless steel.

 

Water storage tank

7

 

Stainless steel water storage tank ensure automatic water replenishment, and is equipped with a liquid level display device, low liquid level alarm device and overflow and  venting  device.

 


Product detail pictures:

OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures


Related Product Guide:

With advanced technologies and facilities, strict high-quality handle, reasonable rate, superior services and close co-operation with prospects, we are devoted to furnishing the best price for our customers for OEM/ODM Factory Hybrid Water Mist Systems - High pressure water mist fire extinguishing system(2.1) – Anbesec , The product will supply to all over the world, such as: Mexico, French, India, We have a excellent team supplying professional service, prompt reply, timely delivery, excellent quality and best price to our customers. Satisfaction and good credit to every customer is our priority. We are sincerely looking forward to cooperate with customers all over the world. We believe we can satisfy with you. We also warmly welcome customers to visit our company and purchase our products.
This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
5 Stars By Deborah from Mexico - 2018.11.06 10:04
This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
5 Stars By Rigoberto Boler from Johannesburg - 2017.12.19 11:10

Send your message to us: