OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1) – Anbesec

Short Description:


Product Detail

Related Video

Feedback (2)

we can easily offer you high-quality products and solutions, competitive rate and very best shopper support. Our destination is "You come here with difficulty and we give you a smile to take away" for Resettable Linear Heat Detector, Water Mist Systems Combine, Linear Detector, We sincerely welcome both equally international and domestic company associates, and hope to work along with you during the in close proximity to foreseeable future!
OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1) – Anbesec Detail:

High-pressure plunger pump

1

High pressure plunger pump  is one of the core components of high pressure water mist system, our company high-pressure plunger pump adopts foreign advanced technology, it has the advantages of long service life and stable performance. Liquid end is made of brass production.

 

High-pressure plunger pump main technical parameters:

specifications

Flow rate(L/min)

Working pressure(Mpa)

power(KW)

Rotating speed

(r/min)

origin

HAWK-HFR80FR

80

28

42

1450

Italy

Pressure-stabilizing pump

2

The pressure stabilizing pump is to stabilize the pressure in the pipeline. After the zone valve is opened, the pipeline pressure is under The pressure stabilizing pump will start automatically. After running for more than 10 seconds, the pressure still cannot reach 16bar, automatically start the high-pressure main pump. The stabilizer pump is made of stainless steel.

 

 

Pump motor

水泵电机

Our company’s high-pressure water mist automatic fire extinguishing system adopts frequency conversion, speed-adjustable, three-phase asynchronous motor.

When selecting  high pressure water mist fire extinguishing system, the rated speed of the motor should meet the speed requirements of the pump, selection of the power of the motor should be based on the working pressure and the flow rate of the water pump.

N=2PQ*10-2

N—-Motor power(Kw);

O—–Working pressure of water pump(MPa);

P—-Flow of water pump(L/min)

High pressure water mist nozzle

4

 

The high-pressure water mist nozzle consists of the main body of the nozzle, the swirl core of the nozzle, and the nozzle main body, filter screen, filter screen sleeve, etc. Under certain water pressure, the water is atomized by centrifugation, impact, jet and other methods.

 

Community-verified icon

 

Technical parameters:

Specification model Rated flow rate(L/min) Minimum working pressure (MPa) Maximum installation distance (m) Height of installation (m)
XSWT0.5/10 5 10 3 According to the design specification
XSWT0.7/10 7 10 3
XSWT1.0/10 10 10 3
XSWT1.2/10 12 10 3
XSWT1.5/10 15 10 3

Pressure regulating relief valve

5

 

The pressure regulating relief valve is connected with the high-pressure water pump and the water tank, when the main pump pressure is too high, the discharged water can flow back to the storage tank. The pressure regulating relief valve is made of brass.

 

Safety relief valve

6

The pressure value of relief action of the safety relief valve is 16.8MPa, and the safety relief valve also known as safety overflow valve is an automatic pressure relief device driven by medium pressure. The safety relief valve is made of stainless steel.

 

Water storage tank

7

 

Stainless steel water storage tank ensure automatic water replenishment, and is equipped with a liquid level display device, low liquid level alarm device and overflow and  venting  device.

 


Product detail pictures:

OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures


Related Product Guide:

As for competitive charges, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we have been the lowest around for OEM Supply Industrial Fans With Water Mist - High pressure water mist fire extinguishing system(2.1) – Anbesec , The product will supply to all over the world, such as: Malta, Mombasa, Ghana, We adopt advanced production equipment and technology, and perfect testing equipment and methods to ensure our product quality. With our high-level talents, scientific management, excellent teams, and attentive service, our products are favored by domestic and foreign customers. With your support, we will build a better tomorrow!
We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
5 Stars By Jamie from Melbourne - 2017.08.18 11:04
This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
5 Stars By Polly from Libya - 2018.04.25 16:46

Send your message to us: