We always believe that one's character decides products' quality, the details decides products' high-quality ,together with the REALISTIC,EFFICIENT AND INNOVATIVE crew spirit for Fire Detection Solutions, Water Mist Sprinkler System, Water Mist Extinguisher, We will supply best quality, the most market competitive price, for every new and old customers with the most perfect green services.
OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1) – Anbesec Detail:

High-pressure plunger pump

1

High pressure plunger pump  is one of the core components of high pressure water mist system, our company high-pressure plunger pump adopts foreign advanced technology, it has the advantages of long service life and stable performance. Liquid end is made of brass production.

 

High-pressure plunger pump main technical parameters:

specifications

Flow rate(L/min)

Working pressure(Mpa)

power(KW)

Rotating speed

(r/min)

origin

HAWK-HFR80FR

80

28

42

1450

Italy

Pressure-stabilizing pump

2

The pressure stabilizing pump is to stabilize the pressure in the pipeline. After the zone valve is opened, the pipeline pressure is under The pressure stabilizing pump will start automatically. After running for more than 10 seconds, the pressure still cannot reach 16bar, automatically start the high-pressure main pump. The stabilizer pump is made of stainless steel.

 

 

Pump motor

水泵电机

Our company’s high-pressure water mist automatic fire extinguishing system adopts frequency conversion, speed-adjustable, three-phase asynchronous motor.

When selecting  high pressure water mist fire extinguishing system, the rated speed of the motor should meet the speed requirements of the pump, selection of the power of the motor should be based on the working pressure and the flow rate of the water pump.

N=2PQ*10-2

N—-Motor power(Kw);

O—–Working pressure of water pump(MPa);

P—-Flow of water pump(L/min)

High pressure water mist nozzle

4

 

The high-pressure water mist nozzle consists of the main body of the nozzle, the swirl core of the nozzle, and the nozzle main body, filter screen, filter screen sleeve, etc. Under certain water pressure, the water is atomized by centrifugation, impact, jet and other methods.

 

Community-verified icon

 

Technical parameters:

Specification model Rated flow rate(L/min) Minimum working pressure (MPa) Maximum installation distance (m) Height of installation (m)
XSWT0.5/10 5 10 3 According to the design specification
XSWT0.7/10 7 10 3
XSWT1.0/10 10 10 3
XSWT1.2/10 12 10 3
XSWT1.5/10 15 10 3

Pressure regulating relief valve

5

 

The pressure regulating relief valve is connected with the high-pressure water pump and the water tank, when the main pump pressure is too high, the discharged water can flow back to the storage tank. The pressure regulating relief valve is made of brass.

 

Safety relief valve

6

The pressure value of relief action of the safety relief valve is 16.8MPa, and the safety relief valve also known as safety overflow valve is an automatic pressure relief device driven by medium pressure. The safety relief valve is made of stainless steel.

 

Water storage tank

7

 

Stainless steel water storage tank ensure automatic water replenishment, and is equipped with a liquid level display device, low liquid level alarm device and overflow and  venting  device.

 


Product detail pictures:

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures


Related Product Guide:

We pursue the administration tenet of "Quality is exceptional, Provider is supreme, Name is first", and will sincerely create and share success with all clientele for OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1) – Anbesec , The product will supply to all over the world, such as: Kenya, Netherlands, Egypt, Our company is continuing to serve customers with high quality, competitive price and timely delivery. We sincerely welcome friends from all over the world to cooperate with us and enlarge our business. If you are interested in our products, please feel free to contact us. We would love to provide you with further information.
It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
5 Stars By Betsy from Paris - 2018.06.03 10:17
The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
5 Stars By Martin Tesch from Kenya - 2018.10.01 14:14

Send your message to us: