We provide good power in high-quality and progress,merchandising,revenue and internet marketing and operation for Water Misters For Outside, Mist Water, Water Pump For Misting System, Many years of work experience, we have realized the importance of providing good quality products and the best before-sales and after-sales services.
OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1) – Anbesec Detail:

High-pressure plunger pump

1

High pressure plunger pump  is one of the core components of high pressure water mist system, our company high-pressure plunger pump adopts foreign advanced technology, it has the advantages of long service life and stable performance. Liquid end is made of brass production.

 

High-pressure plunger pump main technical parameters:

specifications

Flow rate(L/min)

Working pressure(Mpa)

power(KW)

Rotating speed

(r/min)

origin

HAWK-HFR80FR

80

28

42

1450

Italy

Pressure-stabilizing pump

2

The pressure stabilizing pump is to stabilize the pressure in the pipeline. After the zone valve is opened, the pipeline pressure is under The pressure stabilizing pump will start automatically. After running for more than 10 seconds, the pressure still cannot reach 16bar, automatically start the high-pressure main pump. The stabilizer pump is made of stainless steel.

 

 

Pump motor

水泵电机

Our company’s high-pressure water mist automatic fire extinguishing system adopts frequency conversion, speed-adjustable, three-phase asynchronous motor.

When selecting  high pressure water mist fire extinguishing system, the rated speed of the motor should meet the speed requirements of the pump, selection of the power of the motor should be based on the working pressure and the flow rate of the water pump.

N=2PQ*10-2

N—-Motor power(Kw);

O—–Working pressure of water pump(MPa);

P—-Flow of water pump(L/min)

High pressure water mist nozzle

4

 

The high-pressure water mist nozzle consists of the main body of the nozzle, the swirl core of the nozzle, and the nozzle main body, filter screen, filter screen sleeve, etc. Under certain water pressure, the water is atomized by centrifugation, impact, jet and other methods.

 

Community-verified icon

 

Technical parameters:

Specification model Rated flow rate(L/min) Minimum working pressure (MPa) Maximum installation distance (m) Height of installation (m)
XSWT0.5/10 5 10 3 According to the design specification
XSWT0.7/10 7 10 3
XSWT1.0/10 10 10 3
XSWT1.2/10 12 10 3
XSWT1.5/10 15 10 3

Pressure regulating relief valve

5

 

The pressure regulating relief valve is connected with the high-pressure water pump and the water tank, when the main pump pressure is too high, the discharged water can flow back to the storage tank. The pressure regulating relief valve is made of brass.

 

Safety relief valve

6

The pressure value of relief action of the safety relief valve is 16.8MPa, and the safety relief valve also known as safety overflow valve is an automatic pressure relief device driven by medium pressure. The safety relief valve is made of stainless steel.

 

Water storage tank

7

 

Stainless steel water storage tank ensure automatic water replenishment, and is equipped with a liquid level display device, low liquid level alarm device and overflow and  venting  device.

 


Product detail pictures:

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures


Related Product Guide:

To be a result of ours specialty and repair consciousness, our corporation has won a good popularity amid consumers everywhere in the environment for OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1) – Anbesec , The product will supply to all over the world, such as: French, United Arab emirates, Slovakia, If you need to have any of our merchandise, or have other items to be produced, make sure you send us your inquiries, samples or in depth drawings. Meanwhile, aiming to develop into an international enterprise group, we look forward to receiving offers for joint ventures and other cooperative projects.
This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
5 Stars By Iris from Manila - 2018.11.22 12:28
In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
5 Stars By Anne from Cambodia - 2018.09.23 18:44

Send your message to us: