It adheres on the tenet "Honest, industrious, enterprising, innovative" to acquire new solutions continuously. It regards prospects, success as its personal success. Let us build prosperous future hand in hand for Fire Detection Solutions, Continuous Line Heat Detector, Testing Water Mist System, We welcome shoppers, business enterprise associations and close friends from all sections with the globe to contact us and seek cooperation for mutual added benefits.
2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1) – Anbesec Detail:

High-pressure plunger pump

1

High pressure plunger pump  is one of the core components of high pressure water mist system, our company high-pressure plunger pump adopts foreign advanced technology, it has the advantages of long service life and stable performance. Liquid end is made of brass production.

 

High-pressure plunger pump main technical parameters:

specifications

Flow rate(L/min)

Working pressure(Mpa)

power(KW)

Rotating speed

(r/min)

origin

HAWK-HFR80FR

80

28

42

1450

Italy

Pressure-stabilizing pump

2

The pressure stabilizing pump is to stabilize the pressure in the pipeline. After the zone valve is opened, the pipeline pressure is under The pressure stabilizing pump will start automatically. After running for more than 10 seconds, the pressure still cannot reach 16bar, automatically start the high-pressure main pump. The stabilizer pump is made of stainless steel.

 

 

Pump motor

水泵电机

Our company’s high-pressure water mist automatic fire extinguishing system adopts frequency conversion, speed-adjustable, three-phase asynchronous motor.

When selecting  high pressure water mist fire extinguishing system, the rated speed of the motor should meet the speed requirements of the pump, selection of the power of the motor should be based on the working pressure and the flow rate of the water pump.

N=2PQ*10-2

N—-Motor power(Kw);

O—–Working pressure of water pump(MPa);

P—-Flow of water pump(L/min)

High pressure water mist nozzle

4

 

The high-pressure water mist nozzle consists of the main body of the nozzle, the swirl core of the nozzle, and the nozzle main body, filter screen, filter screen sleeve, etc. Under certain water pressure, the water is atomized by centrifugation, impact, jet and other methods.

 

Community-verified icon

 

Technical parameters:

Specification model Rated flow rate(L/min) Minimum working pressure (MPa) Maximum installation distance (m) Height of installation (m)
XSWT0.5/10 5 10 3 According to the design specification
XSWT0.7/10 7 10 3
XSWT1.0/10 10 10 3
XSWT1.2/10 12 10 3
XSWT1.5/10 15 10 3

Pressure regulating relief valve

5

 

The pressure regulating relief valve is connected with the high-pressure water pump and the water tank, when the main pump pressure is too high, the discharged water can flow back to the storage tank. The pressure regulating relief valve is made of brass.

 

Safety relief valve

6

The pressure value of relief action of the safety relief valve is 16.8MPa, and the safety relief valve also known as safety overflow valve is an automatic pressure relief device driven by medium pressure. The safety relief valve is made of stainless steel.

 

Water storage tank

7

 

Stainless steel water storage tank ensure automatic water replenishment, and is equipped with a liquid level display device, low liquid level alarm device and overflow and  venting  device.

 


Product detail pictures:

2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures


Related Product Guide:

Our products and solutions are greatly recognized and trustworthy by customers and may fulfill constantly changing financial and social requires for 2021 Latest Design Water Mist Spray System Cost - High pressure water mist fire extinguishing system(2.1) – Anbesec , The product will supply to all over the world, such as: Honduras, Madras, UK, We can meet the various needs of customers at home and abroad. We welcome new and old customers to come to consult & negotiate with us. Your satisfaction is our motivation! Allow us to work together to write a brilliant new chapter!
  • The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Alma from Spain - 2018.10.01 14:14
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Cherry from Austria - 2017.06.16 18:23

    Send your message to us: